Universal in Collaboration with ING.L.A. BOS CHI Italy SINCE 1930 manufactures & suppliers Premium Quality low pressure Air separation plants of all sizes ranging from 50m3/hour to 50,000m3/hour including Cryogenic Tonnage gas plants and liquid plants.![]() |
![]() |
![]() |
![]() Air Compressor |
![]() Purification Unit |
![]() Air Separation Unit |
![]() Control Panel |
![]() Air Compressor |
![]() Purification Unit |
![]() Air Separation Unit |
![]() Turbo Expander |
![]() Control Panel |
![]() Air Compressor |
![]() Pre-Cooler+Purification Unit |
![]() Air Separation Unit |
![]() Turbo Expander |
![]() Control Panel |
![]() ![]() ![]() |
| Al | Air Filter | EX | Main Heat Exchanger |
| AC | Air Compressor | TE1/2 | Turbo Expander |
| PC | Pre-Cooling Unit | E2 | Sub Cooler |
| PU | Purification Unit | C1 | Column |
| P1/2 | Tower1/Tower2 | CR | Condensor Reboiler |
| H | Heater | C2 | Low Pressure Column |
| Production | Oxygen | Nitrogen | Argon |
| Purity | 99.6% | 99.9%-99.99% or 3ppm | 99.5% or5ppm |
| Air Pressure | 0.7Mpa/7Bar | ||
| Normal operating pressure of plant | 0.6 To 0.7Mpa | 0.6 To 0.7Mpa | 0.6 To 0.7Mpa |
| Power Consumption for oxygen | 0.5 To 0.8 KWh/m | Nil | Negligible |
![]() ![]() ![]() ![]() |
2. Pre Cooling System
The second stage of the process uses a low pressure refrigerant for pre-cooling the processed air to temperature around 12 deg c before it enters the purifier.
The air enters a purifier consisting of twin Molecular Sieve driers, working alternatively. The Molecular Sieves remove the Carbon dioxide & moisture from the process air before the air enters Air Separation Unit.
4. Cryogenic Cooling of Air by Turbo (Expander)
The air has to be cooled to sub zero temperatures for liquification & the cryogenic refrigeration & the cooling is provided by highly efficient turbo expander, which cools the air to temperature almost below -165 to-170 deg C.
5. Separation If Liquid Air Into Oxygen and Nitrogen by Air Separation Column
Oil free, moisture free and Carbon Dioxide free air enters into low pressure plate fin type Heat exchanger where the air is cooled below sub zero temperatures by air expansion process in the turbo expander. Due to the excellent thermal efficiency we can achieve a temperature difference delta t as low as 2 deg c at the warm end of these exchangers.
Air gets liquefied when it enters the air separation column & gets separated into oxygen & nitrogen by the process of rectification.
Oxygen is available at the outlet of the ASU at a purity of 99.6%.
Nitrogen is also available t the outlet as a second product at purity of 99.99% upto 3ppm simultaneously without loss of oxygen product.
6. Compression of Oxygen filling in the Cylinder
The final product in the form compressed Oxygen/Nitrogen goes to the high pressure oxygen cylinders at 1 50 bar or upto higher as required.. Or for pipeline supply or captive consumption | Or for liquid plants to fill in cryogenic liquid tanks.