Oxygen Plants | |
| We are ISO 9001 : 2000 Certified Company | |
![]() ![]() ![]() Language Converter: | ![]()
|
| Small Capacity | |||||
| S.No. | Model | UB-25 | UB-30 | UB-40 | UB-50 |
| 1 | Capacity Oxygen Nitrogen | 25CuM/Hr. 80 CuM/Hr. | 30
CuM/Hr. 100 CuM/Hr. | 40
Cum/Hr. 150 Cum/Hr. | 50
Cum/Hr. 200 Cum/Hr. |
| 2 | Purity (Optional upto 99.999%) | 99.6% 96%-96.6% | 99.6% 96%-96.6% | 99.6% 96%-96.6% | 99.6% 96%-96.6% |
| 3 | Power Connected | 55 KW | 70 KW | 80 KW | 95 KW |
| 4 | Power Consumed (abt.) | 40 KW | 45 KW | 60 KW | 70 KW |
| 5 | Power Supply | 415 Volts | 415 Volts | 415 Volts | 415 Volts |
| 6 | Air Capacity | 150 Cum/Hr | 200 Cum/Hr. | 250 Cum/Hr. | 300 Cum/Hr. |
| 7 | Starting Pressure | 60 Kg/sq.cm. | 55 Kg/sq.cm. | 55 Kg/sq.cm. | 55 Kg/sq.cm. |
| 8 | Working Pressure (abt) | 50 Kg/sq.cm. | 40Kg/sq.cm | 40Kg/sq.cm | 40Kg/sq.cm |
| 9 | Starting Time (After Defrost) | 8 Hours | 8 Hours | 7 Hours | 7 Hours |
| 10 | Starting Time (After Tripping) | 40 Mts. | 40 Mts. | 40 Mts. | 40 Mts. |
| 11 | Areas Required | 6M x 8 M | 6 M x 10 M | 8 M x 10M | 8 M x 12 M |
| 12 | Assembly Height | 7 M | 7 M | 7.5 M | 7.5 M |
| 13 | Weight (About) | 14 Tons | 16 Tons | 18 Tons | 19 Tons |
| 14 | Air Separation Column | Type-Boschi | Type-Boschi | Type-Boschi | Type-Boschi |
| MEDIUM CAPACITY | |||||
| S.No. | Model | UB-60 | UB-80 | UB-100 | UB-150 |
| 1 | Capacity Oxygen Nitrogen | 60
CuM/Hr. 200 CuM/Hr. | 80
CuM/Hr. 250 CuM/Hr. | 100
Cum/Hr. 300 Cum/Hr. | 150
Cum/Hr. 500 Cum/Hr. |
| 2 | Purity
Oxygen Nitrogen (Optional) | 99.6% 96%-99.99% | 99.6% 96%-99.99% | 99.6% 96%-99.99% | 99.6% 96%-99.99% |
| 3 | Power Connected | 110 KW | 130 KW | 150 KW | 250 KW |
| 4 | Power Consumed (abt.) | 88 KW | 95 KW | 105 KW | 165 KW |
| 5 | Power Supply | 415 Volts | 415 Volts | 415 Volts | 415 Volts |
| 6 | Air Capacity | 400 Cum/Hr | 400 Cum/Hr. | 600 Cum/Hr. | 900 Cum/Hr. |
| 7 | Starting Pressure | 45 Kg/sq.cm. | 45 Kg/sq.cm. | 45 Kg/sq.cm. | 45 Kg/sq.cm. |
| 8 | Working Pressure (abt) | 40 Kg/sq.cm. | 38 Kg/sq.cm | 36 Kg/sq.cm | 36 Kg/sq.cm |
| 9 | Starting Time (After Defrost) | 8 Hours | 7Hours | 6 Hours | 6 Hours |
| 10 | Starting Time (After Tripping) | 40 Mts. | 30 Mts. | 20 Mts. | 20 Mts. |
| 11 | Areas Required | 12M x 15 M | 12 M x 15 M | 14 M x 15M | 14M x 15 M |
| 12 | Assembly Height | 8.0 M | 9.0 M | 9.5 M | 9.5 M |
| 13 | Weight (About) | 20 Tons | 25 Tons | 30 Tons | 40Tons |
| 14 | Air Separation Column | Type-Boschi | Type-Boschi | Type-Boschi | Type-Boschi |
| HIGH CAPACITY | |||||
| S.No. | Model#1B7EBA | UB-200 | UB-300 | UB-400 | UB-500 |
| 1 | Capacity Oxygen Nitrogen | 200
CuM/Hr. 800 CuM/Hr. | 300
CuM/Hr. 1200 CuM/Hr. | 400
Cum/Hr. 1400 Cum/Hr. | 500
Cum/Hr. 2000 Cum/Hr. |
| 2 | Purity Oxygen Nitrogen(Optional) | 99.6% 96%-99.99% | 99.6% 96%-99.99% | 99.6% 96%-99.99% | 99.6% 96%-99.99% |
| 3 | Power Connected | 300 KW | 400 KW | 600 KW | 750 KW |
| 4 | Power Consumed (abt.) | 220 KW | 330KW | 400 KW | 500KW |
| 5 | Power Supply | 415 Volts | 415 Volts | 415 Volts | 415 Volts |
| 6 | Air Capacity | 1200 Cum/Hr | 1800 Cum/Hr. | 2400 Cum/Hr. | 3000 Cum/Hr. |
| 7 | Starting Pressure | 45 Kg/sq.cm. | 45 Kg/sq.cm. | 45 Kg/sq.cm. | 45 Kg/sq.cm. |
| 8 | Working Pressure (abt) | 36Kg/sq.cm. | 36Kg/sq.cm | 30Kg/sq.cm | 30Kg/sq.cm |
| 9 | Starting Time (After Defrost) | 6Hours | 5Hours | 5Hours | 5 Hours |
| 10 | Starting Time (After Tripping) | 20 Mts. | 20 Mts. | 20 Mts. | 20 Mts. |
| 11 | Areas Required | 14M x 15 M | 15M x 16 M | 15M x 18M | 18M x 20M |
| 12 | Assembly Height | 9.5 M | 9.5 M | 10 M | 10 M |
| 13 | Weight (About) | 50 Tons | 60 Tons | 70 Tons | 80Tons |
| 14 | Air Separation Column | Type-Boschi | Type-Boschi | Type-Boschi | Type-Boschi |